Ngwuputa & HPC Data center PDU
-
18 ọdụ ụgbọ mmiri P34 Smart PDU
Nkọwa PDU:
1. Ntinye ntinye: 3-phase 346-480 VAC
2. Ntinye ugbu a: 3 x 150A
3. mmepụta voltaji: 3-phase 346-480 VAC ma ọ bụ otu-adọ 200 ~ 277 VAC
4. Mwepu: 18 ọdụ ụgbọ mmiri nke 6-pin PA45 Sockets ahaziri na ngalaba atọ
5. Ọdụ ụgbọ mmiri ọ bụla nwere 3P 20A Circuit Breaker (3P 16A/25A nhọrọ)
6. PDU dakọtara maka 3-phase T21 na otu-phase S21
7. Nleba anya na njikwa ON / Gbanyụọ nke ọdụ ụgbọ mmiri ọ bụla
8. Ntinye ihe nleba anya nke ugbua, voltaji, ike, ihe ike, KWH
9. Onboard LCD ngosi na njikwa menu
10. Ethernet / RS485 interface, na-akwado HTTP / SNMP / SSH2 / MODBUS
11. Internal fan na LED egosi
-
3 ọdụ ụgbọ mmiri P34 Smart PDU
Nkọwa PDU:
1. Ntinye ntinye: 3-phase 346-480 VAC
2. Ntinye ugbu a: 3 x 30A
3. eriri ntinye: L22-30P plọg nwere eriri UL ST 10AWG 5/C 6FT
4. voltaji mmepụta: 3-phase 346-480 VAC ma ọ bụ otu-adọ 200 ~ 277 VAC
5. Mwepu: 3 ọdụ ụgbọ mmiri nke 6-pin PA45 (P34), 3-phase/otu-phase dakọtara
6. Integrated 3P 30A isi sekit breaker
7. Nleba anya na njikwa ON / Gbanyụọ nke ọdụ ụgbọ mmiri ọ bụla
8. Ntinye nlekota anya & kwa ọdụ ụgbọ mmiri, voltaji, ike, PF, KWH
9. Smart Mita nwere interface Ethernet/RS485, nkwado http/snmp/ssh2/modbus
10. Onboard LCD ngosi na njikwa menu na nlekota mpaghara
-
30 ọdụ ụgbọ mmiri P34 Smart PDU
Nkọwa PDU:
1. Ntinye ntinye: 3-phase 346-480 VAC
2. Ntinye ugbu a: 3 x 250A
3. mmepụta voltaji: 3-phase 346-480 VAC ma ọ bụ otu-adọ 200 ~ 277 VAC
4. Mwepu: 30 ọdụ ụgbọ mmiri nke 6-pin PA45 Sockets ahaziri na ngalaba atọ
5. Ọdụ ụgbọ mmiri ọ bụla nwere 3P 30A UL489 Circuit Breaker
6. PDU dakọtara maka 3-phase T21 na otu-phase S21
7. Ntinye ihe nleba anya nke ugbua, voltaji, ike, ihe ike, KWH
8. Onboard LCD ngosi na njikwa menu
9. Ethernet / RS485 interface, na-akwado HTTP / SNMP / SSH2 / MODBUS
10. Internal venting fan na ọkwa LED egosi
-
16 ọdụ ụgbọ mmiri L7-20R Smart PDU
Nkọwa PDU:
1. Ntinye ntinye: 3-phase 346-480 VAC
2. Ntinye ugbu a: 3 x 200A
3. mmepụta voltaji: otu-phase 200 ~ 277 VAC
4. Mwepu: 16 ọdụ ụgbọ mmiri nke L7-20R Sockets
5. Ọdụ ụgbọ mmiri ọ bụla nwere 1P 25A Circuit Breaker
6. Ntinye ihe nleba anya nke ugbua, voltaji, ike, ihe ike, KWH
7. Onboard LCD ngosi na njikwa menu
8. Ethernet / RS485 interface, na-akwado HTTP / SNMP / SSH2 / MODBUS
-
24 ọdụ ụgbọ mmiri P34 Smart PDU
Nkọwa PDU:
1. Ntinye ntinye: 3-phase 346-480 VAC
2. Ntinye ugbu a: 3 x 200A
3. mmepụta voltaji: 3-phase 346-480 VAC ma ọ bụ otu-adọ 200 ~ 277 VAC
4. Mwepu: 24 ọdụ ụgbọ mmiri nke 6-pin PA45 Sockets haziri na ngalaba atọ
5. Onye ọ bụla 3P 25A Circuit Breaker na-achịkwa oghere 3
6. PDU dakọtara maka 3-phase T21 na otu-phase S21
7. Nleba anya na njikwa ON / Gbanyụọ nke ọdụ ụgbọ mmiri ọ bụla
8. Ntinye ihe nleba anya nke ugbua, voltaji, ike, ihe ike, KWH
9. Onboard LCD ngosi na njikwa menu
10. Ethernet / RS485 interface, na-akwado HTTP / SNMP / SSH2 / MODBUS
11. Internal fan na LED egosi
-
16 ọdụ ụgbọ mmiri P34 Smart PDU
Nkọwa PDU:
1. Ntinye ntinye: 3-phase 346-480 VAC
2. Ntinye ugbu a: 3 x 300A
3. mmepụta voltaji: 3-phase 346-480 VAC ma ọ bụ otu-adọ 200 ~ 277 VAC
4. Mwepu: 16 ọdụ ụgbọ mmiri nke 6-pin PA45 Sockets ahaziri na ngalaba atọ
5. Ọdụ ụgbọ mmiri ọ bụla nwere 3P 25A Circuit Breaker
6. PDU dakọtara maka 3-phase T21 na otu-phase S21
7. Nleba anya na njikwa ON / Gbanyụọ nke ọdụ ụgbọ mmiri ọ bụla
8. Ntinye ihe nleba anya nke ugbua, voltaji, ike, ihe ike, KWH
9. Onboard LCD ngosi na njikwa menu
10. Ethernet / RS485 interface, na-akwado HTTP / SNMP / SSH2 / MODBUS
11. Internal fan na LED egosi
-
12 ọdụ ụgbọ mmiri C19 Ngwuputa PDU
Nkọwa PDU:
1. Ntinye ntinye: 3-phase 346-480 VAC
2. Ntinye ugbu a: 3 x 80A
3. mmepụta voltaji: otu-phase 200 ~ 277 VAC
4. Mwepu: 12 ọdụ ụgbọ mmiri nke C19 Sockets
5. Ọdụ ụgbọ mmiri ọ bụla nwere 1P 20A Circuit Breaker
-
18 ọdụ ụgbọ mmiri SA2-30 Ngwuputa PDU
Nkọwa PDU:
1. Ntinye ntinye: 3-phase 346-480 VAC
2. Ntinye ugbu a: 3 x 200A 3. voltaji mmepụta: 3-phase 346-480 VAC
4. Mwepu: 18 ọdụ ụgbọ mmiri nke 3-phase SA2-30 Sockets, 2 C13 oghere.
5. Ọdụ ụgbọ mmiri ọ bụla nwere 3P 20A Circuit Breaker
-
26 ọdụ ụgbọ mmiri L16-30R Smart PDU
Nkọwa PDU:
1. Ntinye ntinye: nkeji atọ 346-415VAC
2. Ntinye ugbu a: 3 x 200A
3. Ejikọtara 250A LS MCCB
4. Mmepụta ugbu a: nkeji atọ 346-415VAC
5. Ngwongwo mmepụta: 26 ọdụ ụgbọ mmiri L16-30R na 1 ọdụ ụgbọ mmiri C13
6. Onye ọ bụla ọdụ ụgbọ mmiri L16-30R nwere UL489 3P 20A hydraulic magnetik sekit breaker, ọdụ ụgbọ mmiri C13 nwere 1P 2A hydraulic magnetik circuit breaker.
7. Ihe mmepụta ọ bụla nwere interface netwọk kwekọrọ
8. Ntinye anya PDU ntinye anya na ọdụ ụgbọ mmiri ọ bụla, voltaji, ike, KWH
9. Mgbanwe njikwa anya na / gbanyụọ ọdụ ụgbọ mmiri ọ bụla
-
24 ọdụ ụgbọ mmiri C19 PDU nwere mgbanwe netwọkụ
Nkọwa PDU:
1. Shell Ihe: 1.2 SGCC Agba: Black ntụ ntụ
2. Voltaji ntinye: 380-433Vac, WYE, 3N, 50/60 HZ
3. Voltage mmepụta: 220-250Vac
4. Max. Ugbu a: 160A
5. oghere mmepụta: ọdụ ụgbọ mmiri 24 C19 kwadoro 250V/20A
6. Usoro njikwa na nchebe: Onye ọ bụla anọ 80A mmiri magnetism Breaker
7. Waya dị n'ime: Isi waya 2 * 5AWG, ahịrị alaka 12AWG
-
18 ọdụ ụgbọ mmiri L7-30R Ngwuputa PDU
Nkọwa PDU:
1. Ntinye ntinye: nkeji atọ 346-480VAC
2. Ntinye ugbu a: 3 x 200A
3. Ejikọtara 200A Fuse maka nkeji atọ
4. Mmepụta ugbu a: otu nkeji 200-277VAC
5. Mpempe akwụkwọ mmepụta: 18 ọdụ ụgbọ mmiri L7-30R
6. Ọdụ ụgbọ mmiri ọ bụla nwere UL489 1P 32A hydraulic magnetik circuit breaker
7. Enwere ike ịrụ ọrụ ọdụ ụgbọ mmiri atọ ọ bụla na-ewepụghị mkpuchi PDU
8. Onye na-eku ume ikuku nke ime na 1P / 2A circuit breaker
-
10 ọdụ ụgbọ mmiri L16-30R Ngwuputa PDU
Nkọwa PDU:
1. Ntinye ntinye: 3-phase 346-480VAC
2. Ntinye ugbu a: 3 x 250A
3. voltaji mmepụta: 3-phase 346-480 VAC
4. Mwepu: 10 ọdụ ụgbọ mmiri nke L16-30R Sockets
5. Ọdụ ụgbọ mmiri ọ bụla nwere 3P 30A Circuit Breaker